首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   40篇
  免费   3篇
  国内免费   2篇
化学   42篇
物理学   3篇
  2022年   1篇
  2021年   2篇
  2020年   6篇
  2019年   4篇
  2018年   4篇
  2017年   1篇
  2016年   1篇
  2015年   1篇
  2014年   1篇
  2013年   3篇
  2012年   2篇
  2011年   1篇
  2010年   3篇
  2007年   1篇
  2006年   3篇
  2005年   5篇
  2003年   2篇
  2002年   1篇
  1994年   1篇
  1993年   1篇
  1979年   1篇
排序方式: 共有45条查询结果,搜索用时 199 毫秒
1.
Slow-channel congenital myasthenic syndromes (SCCMSs) are rare genetic diseases caused by mutations in muscle nicotinic acetylcholine receptor (nAChR) subunits. Most of the known SCCMS-associated mutations localize at the transmembrane region near the ion pore. Only two SCCMS point mutations are at the extracellular domains near the acetylcholine binding site, α1(G153S) being one of them. In this work, a combination of molecular dynamics, targeted mutagenesis, fluorescent Ca2+ imaging and patch-clamp electrophysiology has been applied to G153S mutant muscle nAChR to investigate the role of hydrogen bonds formed by Ser 153 with C-loop residues near the acetylcholine-binding site. Introduction of L199T mutation to the C-loop in the vicinity of Ser 153 changed hydrogen bonds distribution, decreased acetylcholine potency (EC50 2607 vs. 146 nM) of the double mutant and decay kinetics of acetylcholine-evoked cytoplasmic Ca2+ rise (τ 14.2 ± 0.3 vs. 34.0 ± 0.4 s). These results shed light on molecular mechanisms of nAChR activation-desensitization and on the involvement of such mechanisms in channelopathy genesis.  相似文献   
2.
Effects of BaCl_2 on slow vacuolar ion channels on radish by patch-clamp   总被引:2,自引:0,他引:2  
Effects of BaCl2 on slow vacuolar ion channels on radish by patch-clamp YANG Pin (杨 频) & ZHANG Liping (张丽平) Institute of Molecular Science, Shanxi University, Taiyuan 030006, China Correspondence should be addressed to Yang Pin (email: yangpin@sxu.edu.cn)  相似文献   
3.
刘楠  高志贤 《分析化学》2007,35(5):638-642
本研究用膜片电极支撑双层类脂膜(BLMs)核酸传感器,检测葡萄球菌肠毒素B(SEB)基因。BLMs在膜片钳尖端形成后,传感器的检测电流大小和施加的电压成正比。通过在BLMs上固定针对SEB基因特异的直链十二烷烃链(0~273.65μg/L)修饰的单链寡核苷酸(C12-ssDNA)探针与膜片钳系统一同构建成膜片电极支撑BLMs核酸传感器。电流大小与探针的浓度呈正相关,线性回归方程I=5.49 2.94C;相关系数r=0.9962。SEB基因浓度在20~5000μg/L范围时,检测的电流信号与SEB基因浓度的自然对数呈负相关,线性回归方程I=1103.26-103.62lnC,相关系数r=0.9977;同时,核酸传感器有很好的特异性,与不产SEB的金葡菌属、其它食物中毒菌的基因组DNA和空白对照组反应无明显电信号响应。应用原子力显微镜对BLMs表面微观结构、ssDNA固定于BLMs上和BLMs上杂交洗脱后的表面微观结构进行观察。本研究构建的膜片电极支撑BLMs核酸传感器为SEB基因的检测提供了一种快速、灵敏、特异性强的方法。  相似文献   
4.
Disposable pipette tips extraction consists of a solid‐phase extraction in which the sorbent is poorly dispersed in a pipette tip, which allows a quick and dynamic contact between the aspirated analyte from the sample and the solid phase. It is a technique used particularly in food and forensic analysis, since it requires a small amount of sample and solvent. This article highlights the principles, advantages and disadvantages of the disposable pipette tips extraction method and reviews recent applications.  相似文献   
5.
Peptide samples derived from enzymatic in‐gel digestion of proteins resolved by gel electrophoresis often contain high amount of salts originating from reaction and separation buffers. Different methods are used for desalting prior to matrix‐assisted laser desorption/ionization (MALDI) mass spectrometry (MS), e.g. reversed‐phase pipette tip purification, on‐target washing, adding co‐matrices, etc. As a suitable matrix for MALDI MS of peptides, α‐cyano‐4‐hydroxycinnamic acid (CHCA) is frequently used. Crystalline CHCA shows the ability to bind peptides on its surface and because it is almost insoluble in acidic water solutions, the on‐target washing of peptide samples can significantly improve MALDI MS signals. Although the common on‐target washing represents a simple, cheap and fast procedure, only a small portion of the available peptide solution is efficiently used for the subsequent MS analysis. The present approach is a combination of the on‐target washing principle carried out in a narrow‐end pipette tip (e.g. GELoader tip) and preconcentration of peptides from acidified solution by passing it through small CHCA crystals captured inside the tip on a glass microfiber frit. The results of MALDI MS analysis using CHCA‐tip peptide preconcentration are comparable with the use of homemade POROS R2 pipette tip microcolumns. Advantages and limitations of this approach are discussed. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   
6.
The availability of a sensitive and rapid analytical method for the determination of opiates, and other substances of forensic interest, in a variety of biological specimens is of utmost importance to forensic laboratories. Solid-phase extraction is very popular in the pre-treatment of forensic samples. Nevertheless, a new approach, disposable pipette extraction (DPX), is gaining increasing interest in sample preparation. DPX has already been applied to the analysis of drugs of abuse in common biological matrices, such as urine and blood, but has not yet been evaluated on alternative biological samples, such as vitreous humor. The objective of this study was to evaluate the applicability of DPX on the analysis of opiates in vitreous humor. The currently developed method is fast, reliable, and easy to perform. The sensitivity, precision, and accuracy are satisfactory. Recoveries obtained are within the range of 72-91%, whereas the sample volume of vitreous humor required is only 100 μL.  相似文献   
7.
Applying the patch-clamp technique to vacuoles from Radish we studied the effects of Cu2 on Slow Vacuolar (SV) current’s characteristic. Our results show that Cu2 in bath solution at higher concentration inhibits SV currents and the percentage of inhibition increases with increasing concentration and changes with different voltage. When at lower concentration, Cu2 significantly promotes the SV currents and the promotion ratio decrease with increasing voltage. At the same time, the time constants of activation become lesser after adding Cu2 . These results show that there may be some Cu2 binding sites on SV channels and binding to which can change SV current’s characteristic.  相似文献   
8.
In order to improve the permeation and adsorption properties of graphene oxide, heteroatoms and deep eutectic solvent were introduced in this study. After being modified, the structural properties of graphene oxide were improved and the materials were applied to the determination of myricetin and rutin in tea sample by pipette‐tip solid‐phase extraction method. The materials were characterized by scanning electron microscopy, Fourier transform infrared spectroscopy, X‐Ray diffractomer, energy dispersive spectroscopy, atomic force microscope, and specific surface area by Brunauer–Emmett–Teller N2 adsorption desorption analysis. Meanwhile, they were tested by static and dynamic adsorption. The result showed that the materials after modifying had better adsorption amount for myricetin and rutin than graphene oxide. The calibration graphs of myricetin and rutin in MeOH were linear over 0.10–500.00 µg/mL, and the limits of detection and quantification were in the range of 0.00546–0.0182 µg/mL and 0.00741–0.0247 µg/mL, respectively. A reliable analytical method was developed for recognition targets in tea sample by DES modified nitrogen‐doped graphene oxide with satisfactory extraction recoveries (myricetin 99.77%, rutin 98.14%). It was potential for the rapid purification of myricetin and rutin in tea sample combined with the pipette‐tip solid‐phase extraction.  相似文献   
9.
Four commonly found pesticides (alachlor, atrazine, metolachlor, and simazine) in surface water were determined using dispersive pipette extraction followed by gas chromatography–mass spectrometry. The rapid mixing and equilibrium between the dispersive pipette extraction adsorbent and water sample resulted in fast and efficient extraction. Using only 5?mL of water sample, the estimated time consumption for extraction of each sample was less than 5?min. Method validation was performed to evaluate accuracy, precision, linearity, the limits of detection, and the limits of quantitation. Average recovery of above 90% was obtained with relative standard deviations below 10%, which indicated good accuracy and precision of the dispersive pipette extraction method. Coefficients of determination were all above 0.9901 and showed good linearity. For the four pesticides studied using the current method, the limits of detection ranged from 7 to 40?ng?L?1, and limits of quantitation were from 20 to 130?ng?L?1. Method validation results supported the application of the current method for drinking water safety monitoring per National Primary Drinking Water Regulations established by the US Environmental Protection Agency. Water samples from Lake Lanier and Stone Mountain Lake (Georgia, USS) were analyzed with this method as a preliminary work for a larger scale drinking water quality study in the future. Trace amounts of simazine and atrazine were found in lake water samples, but both were below the regulation levels of the US Environmental Protection Agency.  相似文献   
10.
The shortage of ready to use small sized liquid propulsion and switching devices for microfluidic cells (μ-cell) is a bottleneck in the dissemination of micro-flow analysis (μ-FA), now that microfluidic electrochemical cells can be designed and assembled in any laboratory by thermal transfer of laser printed masks and CD-Rs. Microprocessor-controlled electronic pipettors, commercially available with minimum capacity of 10 μL, represent a compromise solution between oversized peristaltic pumps and tiny “on a chip” micropumps and valves. The versatility of the electronic pipette coupled with the μ-cell (13-μm deep longitudinal channel) was demonstrated in three operation modes: SIA like, FIA like and direct injection analysis (DIA). Injections of 100 nL K4Fe(CN)6 (0.1 mol L−1 KCl) define a linear analytical curve (r = 0.999) in the range of 5 × 10−7 to 1.0 × 10−3 mol L−1 for flow amperometry at a gold electrode potentiostated at 0.4 V versus Ag/AgCl. Methods for the amperometric μ-flow determination of promethazine (FIA like), dipyrone (SIA like) and chlorpromazine (DIA) in pharmaceutical formulations were developed and applied to real samples. Excellent linearity of analytical curves and high repeatability (R.S.D. < 3.0%) at the low picomole range was obtained and all results for real samples were in agreement with reference methods. The results reflect the stability and the reliability of the setups envisioned for the electronic pipette coupled with amperometric μ-cell and the validity of the μ-FA methods.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号